LCR Meter

Description

precision lcr meter

Model :LW2812C

Digital LCR Meter : 100Hz,1KHz,100KHz±0.02%

 

Features:

Base on single micro-processor, using advanced 5 ports techniques and micro-processor corrected errors.

Impact protection, locking range and special zeroing function.

Easy operation, high stability, suitable for testing production field.

 

Specifications:

1.Measuring parameters:L ,C, R ,Q, D

2. Measuring frequency

LW2811C:100Hz,1KHz,10KHz±0.02%

LW2812C:100Hz,1KHz,100KHz±0.02%

 

3. Measuring range

Parameters

Frequency

Measuring range

L

100Hz

1μH~9999H

1KHz

0.1μH~999.9H

100KHz

0.01μH~99.99H

C

100Hz

1pF~9999μF

1KHz

0.1pF~999.9μF

100KHz

0.1pF~99.99μF

R

0.1Ω~99.99MΩ

Q

0.001~9999

D

0.0001~9.999

 

4.Measuring accuracy

Parameters

Frequency

Measuring accuracy

L

100Hz

±[1μH+0.25%(1+L/200H+2mH/L)](1+1/Q)

1KHz

±[0.1μH+0.25%(1+L/200H+0.2mH/L)](1+1/Q)

100KHz

±[0.01μH+0.5%(1+L/10H+0.04mH/L)](1+1/Q)

C

100Hz

±[1pF+0.25%(1+1000pF/Cx+Cx/1000μF)](1+Dx)

1KHz

±[0.1pF+0.25%(1+100pF/Cx+Cx/100μF)](1+Dx)

100KHz

±[0.01pF+0.5%(1+20pF/Cx+Cx/4μF)](1+Dx)

R

±[1mΩ+0.25%(1+R/2MΩ+2Ω/R)](1+Q)

Q

100Hz, 1KHz

±[0.020+0.15(Qx+1/Qx)%]

100KHz

±[0.020+0.2(Qx+1/Qx)%]

D

100Hz, 1KHz

±0.0010(1+Dx2)

100KHz

±0.0015(1+Dx2)

 

5.Test signal level:0.3Vrms±10% (Empty) @ 1 KHz

6.Testing speed:4-6 times per second

7.Temperature:0℃~40℃

8.Humidity:less than 85% RH

9.Supply voltage:Voltage:AC198V~242V  50Hz±5%

Power consumption : less than 30W

10.Volume and weight

Dimensions:LW-2812C : 360×320×140mm

Weigh: about 3.5Kg